Mã lỗi L4 01 — Sharp AR5132
Code:
L4 01
Description: Main motor lock detected. Motor lock signal is detected for 1.5 seconds during main motor rotation
Causes: Main motor defective Improper connection of harness between PCU PWB and main motor Control circuit defective
Remedy: Check main motor operation with SIM25-1. Check harness and connector between PCU PWB and main motor.