Code: L6 10
Description: Polygon motor lock detected. It was judged that there is no output of polygon motor lock signal of LSU. The lock signal was checked at about 10-second intervals after the polygon motor started rotating. As result, it was judged that the polygon motor failed to operate normally.
Causes: Disconnected connecter to LSU or detached harness inside LSU or broken wire. Polygon motor defective
Remedy: Check polygon motor operation with SIM61-1. Check harness and connector for connection. Replace LSU if needed.