Mã lỗi C14 — Sharp AR650

Code: C14

Description: Abnormal 2nd cassette tray (Paper can be fed from cassettes other than the 2nd cassette.)
Remedy: Does the tray go up? (Perform the output check in the test mode: 03-242, 243) NO 1. Check if the connector of the tray-up motor is disconnected. 2. Check if the connector J311 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[6]/[H], /[7]/[H]) NO 1. Check if the connector of the sensor is disconnected. 2. Check if the connector J310 on the LGC board is disconnected. 3. Check if the slit reaches the sensor. 4. Check if the connector pins are disconnected and the harnesses are open-circuited. 5. Check if the conductor pattern on the LGC board is short- or open-circuited. 6. Replace the LGC board. YES 1. Check if the conductor pattern on the LGC board is short- or open-circuited. 2. Replace the LGC board.