Mã lỗi E47 — Sharp AR800

Code: E47

Description: Exit cover opened during printing
Remedy: Is the feeds cover close? YES Remove paper if there is any, then close the cover. NO Is the voltage of 24V being supplied from the power supply unit? (Perform the input check in the test mode: 03-[ENERGY SAVER] ON/[1]/[A]) NO 1. Check if the connector for 24V power supply is disconnected. 2. Check if the connector J344 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the LGC board. YES Is the exit cover open/close switch working? (Perform the input check in the test mode: 03-[ENERGY SAVER]OFF/[6]/[H] NO 1. Check if the connector of the front cover opening/closing switch is disconnected. 2. Check if the connector J335 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are opencircuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the exit cover open/close switch. 6. Replace the LGC board. YES Replace the LGC board.