Code: C44
Description: Abnormal fuser after abnormality judgment
Remedy: 1,2.3. Check the thermistors, IH control board, IH coil and LGC board Check the above components following the procedure 1, 2 and 3 for [C41]. 4. Clear the status counter Change the current status counter value (08-400) “4” to “0” for [C43] and “5”, “7” or “9” to “0” for [C44], taking the same procedure as that for [C41]. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred during warming-up: "4" or "5" • The error occurred after the machine has become ready: "6" • The temperature detected by the center thermistor is 230°C or higher: "9" • The temperature detected by the side thermistor is 270°C or higher: "9"counter value (08-400) “6” to “0”.