Mã lỗi CA1 — Sharp AR810

Code: CA1

Description: Abnormal polygonal motor
Remedy: Is the polygonal motor rotating? NO 1. Check if the connector J302 on the LGC board is disconnected. 2. Check if the connector J203 on the POL board is disconnected. 3. Check if the harness is open-circuited and the connector pin is disconnected. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the laser optical unit. 6. Replace the LGC board. YES Are the pins-3 and -4 of the connector J203 on the POL board always level “L”? NO 1. Check if the conductor pattern on the LGC board is short- or open-circuited. 2. Replace the laser optical unit. 3. Replace the LGC board. YES 1. Check if the conductor pattern on the LGC board is short- or open-circuited. 2. Replace the LGC board.