Mã lỗi U5 03 — Sharp ARBC260
Code:
Tất cả lỗi (116)
C2 10
E7 01
E7 07
E7 10
E7 11
E7 20
E7 21
E7 22
E7 23
E7 24
E7 25
E7 26
E7 27
E7 28
E7 40
E7 41
E7 80
E7 90
F1 00
F1 02
F1 03
F1 06
F1 10
F1 11
F1 15
F1 19
F1 20
F1 31
F1 32
F1 33
F1 34
F1 35
F1 36
F1 37
F1 38
F1 39
F1 40
F1 83
F1 89
F1 91
F2 15
F2 16
F2 17
F2 18
F2 19
F2 39
F2 40
F2 41
F2 42
F2 43
F2 44
F2 45
F2 58
F2 70
F2 71
F2 72
F2 73
F2 74
F2 75
F2 76
F2 77
F2 78
F2 80
F2 81
F2 82
F2 83
F2 84
F2 85
F2 86
F2 87
F2 90
F3 12
F9 00
F9 01
F9 03
F9 20
H2 00
H2 01
H3 00
H3 01
H4 00
H4 01
H5 01
H8 01
L1 00
L3 00
L4 02
L4 06
L4 07
L4 11
L8 01
L8 02
L8 04
PF 00
U0 00
U1 02
U2 00
U2 11
U2 30
U2 80
U2 81
U2 90
U2 91
U4 02
U5 00
U5 01
U5 02
U5 03
U5 11
U6 00
U6 01
U6 02
U6 03
U6 10
U7 00
UC 02
Code:
U5 03
Description: ADF timing sensor trouble
Causes: ADF timing sensor detection trouble
Remedy: Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
← Xem tất cả mã lỗi Sharp ARBC260