Mã lỗi F2 44 — Sharp ARBC320

Code: F2 44

Description: Black image density sensor trouble (Transfer belt surface reflection ratio abnormality)
Causes: Before starting process control, the transfer belt surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the output is not within the specified range.
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in SIM 44-2: 1. Dirt/defect of the image density sensor 2. Disconnection of the harness between the PCU PWB and the image density sensor 3. Calibration plate solenoid operation trouble Check & Remedy 1. Clean/replace the image density sensor. 2. Connect/replace the harness between the PCU PWB and the image density sensor. 3. Replace the calibration plate solenoid. Case 2 Cause When SIM 44-2 is completed: 1. Insufficient cleaning of the transfer belt. Check & Remedy 1. Check the transfer belt surface.

← Xem tất cả mã lỗi Sharp ARBC320