Mã lỗi F2 78 — Sharp ARBC320

Code: F2 78

Description: Trouble of image density sensor for registration (Transfer belt surface reflection ratio abnormality)
Causes: Before starting registration, the transfer belt surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the value is not within the specified range.
Remedy: Case 1 Cause Image density sensor trouble, disconnection of the harness between the PCU PWB and the image density sensor, dirt on the image density sensor. Check & Remedy Check the sensor and the harness. Case 2 Cause Calibration plate solenoid operation trouble Check & Remedy Check the calibration plate solenoid operation. Case 3 Cause Insufficient cleaning of the transfer belt. Check & Remedy Check the transfer belt surface.