Code: E7 10
Description: Shading trouble (Black correction)
Causes: "In shading correction, the CCD black reading level is abnormal (with the scanner lamp OFF)."
Remedy: Case 1 Trouble position/cause Bad connection between the CCD unit and the ICU SCAN PWB Remedy (Check) Check connection of the flat cable between the CCD unit and the ICU SCAN PWB. (Repair) Replace the flat cable between the CCD unit and the ICU SCAN PWB. / Power Source-ON Case 2 Trouble position/cause CCD unit trouble Remedy (Check) Check the CCD black offset level (SIM 46-6). / Check the shading correction result (SIM 63-1). (Repair) Replace the CCD unit. / Power Source-ON (After-work) Adjust ADJM17-ADJ1. Note Case 3 Trouble position/cause "ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB trouble" Remedy (Check) (Repair) "Replace ICU SCAN PWB, ICU IMAGE PWB, ICU MAIN PWB." / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)