Code: F2 51
Description: Drum marking detection trouble (CYAN)
Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy: Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.