Mã lỗi H5 2 — Sharp ARC100

Code: H5 2

Description: Paper jam in the fusing/paper exit sections (paper jam winding around the upper fusing roller) (Upper fusing roller temperature distribution abnormality)
Causes: A difference is generated in the upper roller temperature distribution. (A difference between the detected outputs of the fusing main temperature sensor (THS1) and the sub temperature sensor (THS3) is greater than the specified level. (Winding of paper is detected.)
Remedy: Case 1 Trouble position/cause Paper is winding around the fusing roller. Remedy (Check) Check for winding jam of paper around the fusing roller. (Repair) Remove paper winding around the fusing roller. / SIM 14 (After-work) Note Case 2 Trouble position/cause Temperature sensor (Thermistor) trouble Remedy (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14