Code: U4 12
Description: ADU transport motor trouble
Causes: "The motor rotation sensor (RE) signal cycle becomes 50msec or more after 1sec from turning ON the ADU transport motor. / The motor rotation sensor (RE) signal is detected more than 100 times during 100msec after 5sec from turning OFF the ADU transport motor."
Remedy: Case 1 Trouble position/cause Duplex transport motor trouble Remedy (Check) Check the duplex transport motor operation. (SIM9-1/2/4) (Repair) Replace the duplex transport motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Duplex transport motor rotation sensor (DMRE) trouble Remedy (Check) Duplex transport motor rotation sensor (DMRE) operation check (SIM 9-1/2/4) (Repair) Replace the duplex transport motor rotation sensor (DMRE). / Power Source-ON (After-work) Note Case 3 Trouble position/cause Duplex mechanism section trouble Remedy (Check) Duplex mechanism section operation check (SIM9-1/2/4) (Repair) Repair or replace the duplex mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause ADU control PWB trouble Remedy (Check) (Repair) ADU control PWB replacement / Power Source-ON