Code: U5 0
Description: PCU MAIN PWB - RADF communication trouble
Causes: Communication test error in warm-up
Remedy: Case 1 Trouble position/cause Bad connection of the signal line between the PCU MAIN PWB and the RADF control PWB. Remedy (Check) Check connection of the signal line between the PCU MAIN PWB and the RADF control PWB. (Repair) Repair or replace the cable and the connector between the PCU MAIN PWB and the RADF control PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 3 Trouble position/cause RADF control PWB trouble Remedy (Check) (Repair) RADF control PWB replacement / Power Source-ON