Code: H4 1
Description: Fusing section (lower) low temperature trouble (HL2)
Causes: The specified temperature is not reached within the specified time (5 min) after starting warm-up.
Remedy: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Remedy (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Remedy (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14 (After-work) Note Case 4 Trouble position/cause AC main power PWB trouble Remedy (Check) Check the operation of the heater lamp. (SIM 5-2). (Repair) AC main power PWB replacement / SIM 14 (After-work) Note Case 5 Trouble position/cause Interlock switch (door) trouble Remedy (Check) Check the interlock switch (door). (Repair) Replace the interlock switch (door). / SIM 14 (After-work) Note Case 6 Trouble position/cause Thermostat operation or trouble Remedy (Check) Check the thermostat contact. (Repair) Reset or replace the thermostat. / SIM 14 (After-work) Note Case 7 Trouble position/cause Heater lamp trouble Remedy (Check) Check the operation of the heater lamp. (SIM5-2) (Repair) Replace the heater lamp. / SIM 14