Mã lỗi H4 1 — Sharp ARC160

Code: H4 1

Description: Fusing section (lower) low temperature trouble (HL2)
Causes: The specified temperature is not reached within the specified time (5 min) after starting warm-up.
Remedy: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Remedy (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Remedy (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14 (After-work) Note Case 4 Trouble position/cause AC main power PWB trouble Remedy (Check) Check the operation of the heater lamp. (SIM 5-2). (Repair) AC main power PWB replacement / SIM 14 (After-work) Note Case 5 Trouble position/cause Interlock switch (door) trouble Remedy (Check) Check the interlock switch (door). (Repair) Replace the interlock switch (door). / SIM 14 (After-work) Note Case 6 Trouble position/cause Thermostat operation or trouble Remedy (Check) Check the thermostat contact. (Repair) Reset or replace the thermostat. / SIM 14 (After-work) Note Case 7 Trouble position/cause Heater lamp trouble Remedy (Check) Check the operation of the heater lamp. (SIM5-2) (Repair) Replace the heater lamp. / SIM 14

← Xem tất cả mã lỗi Sharp ARC160

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie