Code: U4 2
Description: ADU alignment plate operation trouble
Causes: The home position sensor (DPHPS) detects the home position sensor for 1sec or more after starting separating operation of the alignment plate from the home position. / The home position is not detected within 5sec after starting returning operation to the home position.
Remedy: Case 1 Trouble position/cause Alignment home position sensor (DPHPS) trouble Remedy (Check) Check the alignment home position sensor (DPHPS) operation. (SIM9-1/2/4) (Repair) Replace the alignment home position sensor (DPHPS). / Power Source-ON (After-work) Note Case 2 Trouble position/cause Duplex alignment motor trouble. Remedy (Check) Check the duplex alignment motor operation. (SIM9-1/2/4) (Repair) Replace the duplex alignment motor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Duplex mechanism section trouble Remedy (Check) Check the duplex mechanism section operation. (SIM9-1/2/4) (Repair) Repair or replace the duplex mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause ADU control PWB trouble Remedy (Check) (Repair) ADU control PWB replacement / Power Source-ON