Mã lỗi U6 22 — Sharp ARC160

Code: U6 22

Description: Large capacity tray (LCC) 24V power trouble
Causes: DC24V power is not supplied to the large capacity tray (LCC).
Remedy: Case 1 Trouble position/cause Bad connection between the DC MAIN power PWB and the large capacity tray (LCC) Remedy (Check) "Check connection between the fuse (F708), the DC MAIN power PWB and the large capacity tray (LCC)." (Repair) Replace the fuse (F708). Repair or replace the wire and the connector between the DC MAIN power PWB and the large capacity tray (LCC) control PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Large capacity tray (LCC) control PWB trouble Remedy (Check) (Repair) Large capacity tray (LCC) control PWB replacement / Power Source-ON