Mã lỗi U6 9 — Sharp ARC160

Code: U6 9

Description: Large capacity tray (LCC) lift motor trouble
Causes: The rotation sensor output signal does not change when the lift motor is turned ON. / The rotation sensor output signal changes after turning OFF the lift motor.
Remedy: Case 1 Trouble position/cause Lift motor rotation sensor trouble Remedy (Check) Check the lift motor rotation sensor operation. (Repair) Replace the lift motor rotation sensor. / SIM 15 (After-work) Note Case 2 Trouble position/cause "Lift mechanism (motor, etc.) trouble" Remedy (Check) "Check the lift mechanism (motor, etc.) operation. (SIM4-3)" (Repair) Replace the lift unit (lift motor). / SIM 15 (After-work) Note Case 3 Trouble position/cause Large capacity tray (LCC) control PWB trouble Remedy (Check) (Repair) Replace the large capacity tray (LCC) control PWB. / SIM 15 (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / SIM 15 (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)