Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi F2 81 — Sharp ARC170M

Code: F2 81

Description: Half-tone process control 1st patch error (Cyan)
Causes: 1st step of execution of halftone process control. The low-density rising point or the high-density rising point cannot be calculated from the linear approximation formula of the ratio of the sensor output for the print gradation value obtained from the patch print result. <The trouble is saved in the trouble history, but F2 trouble is not displayed. The operation is made with the previous correction value.>
Remedy: Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.