Mã lỗi F1 06 — Sharp ARC172M
Code:
Tất cả lỗi (125)
A0 00
C2 10
E7 01
E7 07
E7 10
E7 11
E7 20
E7 21
E7 22
E7 23
E7 24
E7 25
E7 26
E7 27
E7 28
E7 30
E7 40
E7 41
E7 80
E7 90
F1 00
F1 02
F1 03
F1 06
F1 10
F1 11
F1 15
F1 19
F1 20
F1 31
F1 32
F1 33
F1 34
F1 35
F1 36
F1 37
F1 38
F1 39
F1 40
F2 39
F2 40
F2 41
F2 42
F2 43
F2 44
F2 45
F2 58
F2 70
F2 71
F2 72
F2 73
F2 74
F2 75
F2 76
F2 77
F2 78
F2 80
F2 81
F2 82
F2 83
F2 84
F2 85
F2 86
F2 87
F2 90
F3 12
F6 00
F6 01
F6 04
F6 20
F6 21
F6 97
F6 98
F7 01
F9 00
F9 01
F9 03
F9 20
H2 00
H2 01
H3 00
H3 01
H4 00
H4 01
H5 01
L1 00
L3 00
L4 02
L4 06
L4 07
L4 11
L8 01
L8 02
L8 04
PF 00
U0 00
U1 01
U1 02
U2 00
U2 11
U2 22
U2 30
U2 80
U2 81
U2 90
U2 91
U4 02
U5 00
U5 01
U5 02
U5 03
U5 11
U6 00
U6 01
U6 02
U6 03
U6 09
U6 10
U6 20
U6 21
U6 22
U6 50
U6 51
U7 00
UC 02
Code:
F1 06
Description: Saddle finisher slide motor trouble
Causes: Slide motor operation trouble
Remedy: Case 1 Cause Motor lock Check & Remedy Use SIM 3-3 to check the motor operation. Case 2 Cause Motor RPM abnormality Check & Remedy Same as Case 1. Case 3 Cause Over current to the motor Check & Remedy Same as Case 1. Case 4 Cause Saddle finisher control PWB trouble Check & Remedy Same as Case 1.
← Xem tất cả mã lỗi Sharp ARC172M