Description: Drum marking detection trouble (CYAN)
Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy: Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.

← Xem tất cả mã lỗi Sharp ARC250

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie