Code: H2 0
Description: Fusing main temperature sensor (upper) (Thermistor) open / Fusing unit not-installed (THS1)
Causes: Fusing main temperature sensor (upper) (Thermistor) output line open (A voltage of 4.6V or above is detected.) / The fusing unit is not installed.
Remedy: Case 1 Trouble position/cause Fusing main temperature sensor (upper) (Thermistor) output line open trouble Remedy (Check) Bad connection between the fusing main temperature sensor (upper)(Thermistor) and the PCU SUB PWB (Repair) Check connection of the fusing main temperature sensor (upper)(Thermistor) and the PCU SUB PWB. / Power Source-ON (After-work) Repair or replace the harness and connector between the fusing main temperature sensor (upper)(Thermistor) and the PCU SUB PWB. Note Case 2 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON