Mã lỗi H3 0 — Sharp ARC250

Code: H3 0

Description: Fusing section high temperature trouble (THS1)
Causes: The fusing temperature rises above 220°C. (The temperature sensor (Thermistor) voltage of 0.85V or less is detected.)
Remedy: Case 1 Trouble position/cause Temperature sensor (Thermistor) trouble Remedy (Check) Check for dirt on the temperature sensor (Thermistor). (Repair) Clean or replace the temperature sensor (Thermistor). / SIM 14 (After-work) Note Case 2 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 3 Trouble position/cause Heater lamp control PWB (AC SUB PWB) trouble Remedy (Check) Check the operation of the heater lamp. (SIM 5-2) (Repair) Replace the heater lamp control PWB (AC SUB PWB). / SIM 14