Mã lỗi L8 01 — Sharp ARC260F
Code:
Tất cả lỗi (116)
C2 10
E7 01
E7 07
E7 10
E7 11
E7 20
E7 21
E7 22
E7 23
E7 24
E7 25
E7 26
E7 27
E7 28
E7 40
E7 41
E7 80
E7 90
F1 00
F1 02
F1 03
F1 06
F1 10
F1 11
F1 15
F1 19
F1 20
F1 31
F1 32
F1 33
F1 34
F1 35
F1 36
F1 37
F1 38
F1 39
F1 40
F1 83
F1 89
F1 91
F2 15
F2 16
F2 17
F2 18
F2 19
F2 39
F2 40
F2 41
F2 42
F2 43
F2 44
F2 45
F2 58
F2 70
F2 71
F2 72
F2 73
F2 74
F2 75
F2 76
F2 77
F2 78
F2 80
F2 81
F2 82
F2 83
F2 84
F2 85
F2 86
F2 87
F2 90
F3 12
F9 00
F9 01
F9 03
F9 20
H2 00
H2 01
H3 00
H3 01
H4 00
H4 01
H5 01
H8 01
L1 00
L3 00
L4 02
L4 06
L4 07
L4 11
L8 01
L8 02
L8 04
PF 00
U0 00
U1 02
U2 00
U2 11
U2 30
U2 80
U2 81
U2 90
U2 91
U4 02
U5 00
U5 01
U5 02
U5 03
U5 11
U6 00
U6 01
U6 02
U6 03
U6 10
U7 00
UC 02
Code:
L8 01
Description: Full wave signal not provided
Causes: The full wave signal is not provided.
Remedy: Case 1 Cause PCU PWB trouble Check & Remedy Replace the PCU PWB. Case 2 Cause Power supply unit trouble Check & Remedy Replace the power supply unit. Case 3 Cause Harness trouble Check & Remedy Check connection of the harness and the connector.
← Xem tất cả mã lỗi Sharp ARC260F