Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi L4 07 — Sharp ARC260FP

Code: L4 07

Description: Transfer belt motor trouble
Causes: 1) Before driving the drum, the calibration plate is opened with the process control BK sensor, and light is emitted with the gain value of 0 and with the light emitting quantity fixed to 120. The average of ten light quantities repeats to be 5 or less for 3 times continuously. 2) Immediately after driving the drum, the calibration plate is opened with the process control BK sensor, and one whole turn of the belt surface is scanned with the gain value of 0 and with the light emitting quantity at the optimum value (120 - 50). The difference between the max. value and the min. value of the scanned data is 5 or less.
Remedy: Case 1 Cause Transfer belt motor connector disconnection, process control sensor connector disconnection, process control BK sensor defect, defective connection of the harness between the PCU PWB and the transfer belt motor, defective control circuit Check & Remedy Check the transfer belt motor operation with SIM25-1. Check the process control sensor operation with SIM44-2. Check the harness and the connector between the PCU PWB and the transfer belt motor.

← Xem tất cả mã lỗi Sharp ARC260FP