Code:
F1 31
Description: Finisher fold sensor trouble
Causes: Sensor input value abnormality
Remedy: Case 1 Cause Sensor breakage Check & Remedy Use SIM 3-2 to check the sensor operation. Case 2 Cause Harness disconnection Check & Remedy Same as case 1. Case 3 Cause Console finisher control PWB trouble Check & Remedy Same as Case 1.