Code: F1 83
Description: Guide bar oscillation motor (M3) lock
Causes: Returning to the home position is not completed in 2sec. When moving from the home position, the home position sensor does not turn off after outputting 20 pulses of the motor drive signal.
Remedy: Common Check Execute SIM 3-2 and 3-3 to check the guide bar drive motor operations and the sensor operations. Case 1 Cause Guide bar home position sensor trouble Check & Remedy Replace the guide bar home position sensor. Case 2 Cause Cable trouble between the guide bar oscillation motor and the sorter controller PWB. Check & Remedy Check and connect the cable properly between the guide bar oscillation motor and the sorter controller PWB. Case 3 Cause The circuit breaker (CB1) is operating. Check & Remedy Remove the cause for operation of the circuit breaker, and reset the circuit breaker. Case 4 Cause There is a mechanical bur in the guide bar shifting path. Check & Remedy Repair the mechanism to remove the bur. Case 5 Cause Guide bar oscillating motor (M3) trouble Check & Remedy Replace the sorter controller PWB, and perform the bin paper sensor sensitivity adjustment and the guide bar motor oscillating range adjustment. Case 6 Cause Sorter controller PWB trouble Check & Remedy Same as Case 5