Code: F1 89
Description: Bin shift motor (M1) lock
Causes: The bin shift motor operation is not completed in 4 times greater than the specified time. When driving the bin shift motor, the signal from the shift motor clock sensor is not detected in 250msec. Shifting to the home position is not completed in 30sec.
Remedy: Common Check Execute SIM 3-2 and 3-3 to check the guide bar drive motor operations and the sensor operations. (Case 1, 2) Check the voltage (about 24V) between J8-1 and J8-2 on the bin shift motor driver PWB at the timing of the bin shift motor. (Case 3 to 5) Case 1 Cause Cable trouble between the bin shift motor and the sorter controller PWB. Check & Remedy Check and connect the cable properly between the bin shift motor and the sorter controller PWB. Case 2 Cause The circuit breaker (CB1) is operating. Check & Remedy Remove the cause for operation of the circuit breaker, and reset the circuit breaker. Case 3 Cause Wiring trouble of the bin shift motor (M1). Check & Remedy Correct wiring of the bin shift motor. Case 4 Cause Bin shift motor trouble Check & Remedy Replace the bin shift motor. Case 5 Cause Sorter controller PWB trouble Check & Remedy Replace the sorter controller PWB, and perform the bin paper sensor sensitivity adjustment and the guide bar motor oscillating range adjustment. Case 6 Cause Bin shift mechanism trouble Check & Remedy Repair the mechanism.