Mã lỗi U4 02 — Sharp ARC262

Code: U4 02

Description: ADU alignment plate operation abnormality
Causes: The alignment plate does not move from the home position within 1sec when it must move. Return to the home position is not detected for 5sec or more.
Remedy: Case 1 Cause Home position sensor trouble Check & Remedy Use SIM 9-2 to detect the home position sensor. Case 2 Cause Alignment plate shift motor trouble Check & Remedy Use SIM 9-4 to check the alignment plate operation. Case 3 Cause Disconnection of the harness between the ADU control PWB and the motor sensor. Check & Remedy Check connection of the harness between the ADU control PWB and the motor sensor. Case 4 Cause Alignment plate operation belt, gear breakage or improper adjustment Check & Remedy Remove the ADU, and check for breakage of the gear and the belt.