Code: F2 90
Description: Half tone correction trouble
Causes: The max. value of the difference (between colors) between the half tone correction value and the previous correction value exceeds the specified level.
Remedy: Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching." (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit" (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10