Code: L6 12
Description: Scanner (writing) motor lock detection (MAGENTA)
Causes: Scanner (writing) unit (LSU) polygon motor lock signal detection trouble (The lock signal is not detected for 10 sec after turning on the polygon motor.)
Remedy: Case 1 Trouble position/cause Scanner (writing) unit (LSU) trouble Remedy (Check) Scanner (writing) unit (LSU) operation check (SIM 61-1) (Repair) Replace the scanner (writing) unit (LSU). / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10 Note Case 2 Trouble position/cause ICU MAIN PWB trouble Remedy (Check) (Repair) ICUMAIN PWB replacement / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.)