Mã lỗi E7 21 — Sharp ARC280

Code: E7 21

Description: Laser beam sensor trouble (CYAN)
Causes: The laser beam sensor cannot detect laser beam. (The sensor signal does not change.)
Remedy: Case 1 Trouble position/cause Bad connection of the signal line between the ICU MAIN PWB and the scanner (writing) unit. Remedy (Check) Check connection between the ICU MAIN PWB and the scanner (writing) unit. (Repair) Replace the cable and the connector between the ICU MAIN PWB and the scanner (writing) unit. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble/Laser beam sensor trouble/Optical system dirt) Remedy (Check) Check the scanner (writing) unit operation. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10. Note Case 3 Trouble position/cause ICU MAIN PWB trouble Remedy (Check) (Repair) Replace the ICU MAIN PWB. / Power Source-ON (After-work) Adjust ADJM9/M10/M12/M13/M14/M15/M17. / Re-enter setup values and adjustment values. (Install the EEPROM of the defective ICU MAIN PWB to a new ICU MAIN PWB.) Note Case 4 Trouble position/cause Scanner (writing) unit power line (24V/5V) trouble Remedy (Check) Check the door switch (DSWF). / Check the fuse (F706). (Repair) Replace the door switch (DSWF). / Replace the fuse (F706). / Power Source-ON