Code: F1 89

Description: Sorter bin shift motor trouble (Sorter side detection)
Causes: The lead cam position sensor signal is not recognized within the specified time after outputting the bin shift motor ON signal. / The guide bar home position is not recognized within the specified time after start of the guide bar operation. / The rotation sensor output signal is not recognized within the specified time after outputting the bin shift motor ON signal.
Remedy: Case 1 Trouble position/cause Bin shift motor trouble / Lead cam position sensor Remedy (Check) Check operations of the bin shift motor / lead cam home position sensor. (SIM3-1/2) (Repair) Replace the bin shift motor. / Replace the lead cam position sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bin shift mechanism section trouble Remedy (Check) Check operations of the bin shift mechanism section. (SIM 3-1/2) (Repair) Repair or replace the parts in the bin shift mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Circuit breaker operation Remedy (Check) Check the cause of an overcurrent. (Repair) Reset the circuit breaker. / Power Source-ON (After-work) Note Case 4 Trouble position/cause Sorter control PWB trouble. Remedy (Check) Check operations of the sorter control PWB.(SIM3-1/2) (Repair) Replace the sorter control PWB. / Power Source-ON

← Xem tất cả mã lỗi Sharp ARC280

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie