Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi F9 0 — Sharp ARC280

Code: F9 0

Description: ICU PWB-printer controller communication trouble (ICU detection)
Causes: "Communication (protocol, data) error"
Remedy: Case 1 Trouble position/cause Printer I/F PWB trouble Remedy (Check) Check the printer I/F PWB. (Repair) Replace the printer I/F PWB. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between the printer controller and the ICU image PWB. Remedy (Check) Check the signal line between the printer controller and the ICU image PWB. (Repair) Repair or replace the cable and the connector between the printer controller and the ICU image PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause ICU IMAGE PWB trouble Remedy (Check) (Repair) ICU IMAGE PWB replacement / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause Printer controller trouble Remedy (Check) Check the printer controller. (Repair) Repair or replace the printer controller. / Power Source-ON

← Xem tất cả mã lỗi Sharp ARC280