Mã lỗi L4 5 — Sharp ARC280

Code: L4 5

Description: Developing motor trouble (COLOR)
Causes: The motor lock signal is detected for 1.5sec or more when the developing motor is ON.
Remedy: Case 1 Trouble position/cause Developing motor trouble Remedy (Check) Check the developing motor operation (SIM 25-1). (Repair) Replace the developing motor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Developing mechanism section trouble Remedy (Check) Check the loads of the developing mechanism section. (Repair) Repair or replace the parts in the developing mechanism section. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause Developing motor power line trouble Remedy (Check) Check the fuse (F707). (Repair) Replace the fuse (F707). / Power Source-ON