Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi U4 2 — Sharp ARC280

Code: U4 2

Description: ADU alignment plate operation trouble
Causes: The home position sensor (DPHPS) detects the home position sensor for 1sec or more after starting separating operation of the alignment plate from the home position. / The home position is not detected within 5sec after starting returning operation to the home position.
Remedy: Case 1 Trouble position/cause Alignment home position sensor (DPHPS) trouble Remedy (Check) Check the alignment home position sensor (DPHPS) operation. (SIM9-1/2/4) (Repair) Replace the alignment home position sensor (DPHPS). / Power Source-ON (After-work) Note Case 2 Trouble position/cause Duplex alignment motor trouble. Remedy (Check) Check the duplex alignment motor operation. (SIM9-1/2/4) (Repair) Replace the duplex alignment motor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Duplex mechanism section trouble Remedy (Check) Check the duplex mechanism section operation. (SIM9-1/2/4) (Repair) Repair or replace the duplex mechanism section. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause ADU control PWB trouble Remedy (Check) (Repair) ADU control PWB replacement / Power Source-ON

← Xem tất cả mã lỗi Sharp ARC280

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie