Mã lỗi F2 43 — Sharp ARC330

Code: F2 43

Description: Toner concentration sensor trouble (YELLOW)
Causes: Toner density sensor output line open
Remedy: Case 1 Trouble position/cause "Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB" Remedy (Check) "Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB." (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Remedy (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)