Mã lỗi F3 22 — Sharp ARC330

Code: F3 22

Description: Lift up trouble (Paper 2)
Causes: Lifting is not completed (LUD2) is not turned ON) within the specified time after turning ON the lift motor.
Remedy: Case 1 Trouble position/cause LUD2 detector trouble Remedy (Check) Check operation of the LUD2 detector (SIM 30-2). (Repair) Replace the LUD2 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause "Lift mechanism (motor, etc..) trouble" Remedy (Check) "Check operations of the lift mechanism section (motor, etc.)." (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Remedy (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)