Mã lỗi H5 1 — Sharp ARC330

Code: H5 1

Description: Paper jam in the fusing/paper exit section
Causes: POD/DPID do not detect 3 sheets of paper continuously.
Remedy: Case 1 Trouble position/cause Paper remaining in the fusing section Remedy (Check) Check for remaining paper. (Repair) Remove remaining paper. / SIM 14 (After-work) Note Case 2 Trouble position/cause POD/DPID detector trouble Remedy (Check) Check operations of POD/DPID detectors. (SIM30-1) (Repair) Replace the POD/DPID detectors. / SIM 14 (After-work) Note Case 3 Trouble position/cause Fusing unit installation trouble Remedy (Check) Check installation of the fusing unit. (Repair) Install the fusing unit properly. / SIM 14 Case 4 Trouble position/cause Fusing unit installation trouble Remedy (Check) (Repair) SIM 14 (After-work) Note Case 5 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB fusing temperature sensor circuit. (Repair) PCU SUB PWB replacement / SIM 14 (After-work) Note Case 6 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / SIM 14 (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)