Code: H4-20
Description: Main heater lamp abnormally low temperature detection
The setup temperature (about 25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power ON SW. (When the temperature falls below 140°C in the standby mode.)
The setup temperature (about 25°C: Sim 43-1-1) is not reached within the specified time (about 32sec) from turning on the power ON SW. (When the temperature falls below 140°C in the standby mode.)
Causes: Main heater thermistor defect Main heater lamp failure Main thermostat failure Control PWB failure
Remedy: Check the main heater lamp blinking with SIM 5-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. When the lamp does not light: Check for disconnection of the heater lamp and thermostat. Check the interlock switch. Check the power PWB and the MCU PWB lamp control circuit. Clear the display of self-diagnostics with SIM 14.