Mã lỗi E1 14 — Sharp ARN275
Code:
Tất cả lỗi (76)
CE 00
CE 01
CE 02
CE 03
CE 04
CE 05
E1 00
E1 10
E1 11
E1 12
E1 13
E1 14
E1 15
E1 16
E1 17
E1 80
E1 81
E1 82
E1 84
E1 88
E7 02
E7 10
E7 11
E7 12
EE EL
EE EU
F1 00
F1 01
F1 06
F1 08
F1 11
F1 15
F2 02
F2 04
F5 02
F6 00
F6 10
F6 80
F6 81
F6 82
F6 84
F6 88
F6 99
F9 00
F9 10
F9 80
F9 81
F9 82
F9 84
F9 88
F9 99
H2 00
H3 00
H4 00
H5 01
H5 02
L1 00
L3 00
L4 01
L4 11
L6 10
L8 01
PF 00
U2 04
U2 11
U2 12
U2 20
U2 40
U7 00
U9 00
U9 80
U9 81
U9 82
U9 84
U9 88
U9 99
Code:
E1 14
Description: IMC board Work RAM error. IMC extended compression memory module installation error IMC extended compression memory access error
Causes: IMC expanded memory module installation trouble IMC expanded memory module trouble IMC expanded memory contact trouble IMC board abnormality
Remedy: Check installation of the expanded memory module. (Spec: Added to Slot 1.) Replace the expanded memory module. Replace the IMC PWB. Extend memory abnormality for compressed image store (DIMM module)