Mã lỗi F1 06 — Sharp ARP450
Code:
F1 06
Description: Console finisher (AR-FN7) slide motor trouble. Slide motor operation abnormality
Causes: Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
Remedy: Use DIAG (SIM3-3) to check the motor operation.