Code: L4 01
Description: Main motor lock. The main motor encoder pulse is not detected for 400msec.
Causes: Main motor defect Harness disconnection between the MCU PWB and the main motor. Control circuit failure
Remedy: Check the main motor operation with SIM 25-1. Check the harness and the connector between the MCU PWB and the main motor.