Code: F2-67
Description: Toner supply abnormality (YELLOW)
Toner end with the remaining quantity of 50% or more. The toner supply time exceeds 3 times as much as the specified time.
Toner end with the remaining quantity of 50% or more. The toner supply time exceeds 3 times as much as the specified time.
Causes: Toner motor section connector harness trouble Toner motor and toner density sensor trouble
Remedy: Case 1 Cause Toner motor section connector harness trouble Check and remedy Check the connector connection of the toner motor section. Check the connector harness (TM) connection to the main PWB. Case 2 Cause Toner motor and toner density sensor trouble Check and remedy Check the toner density sensor output. (SIM25-1) Check that the toner transport pipe is not clogged between the toner cartridge and the developing unit. Replace the toner cartridge (CRUM) if necessary. If replacement of the toner cartridge (CRUM) does not clear the trouble, check the developing unit.