Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi F2-78 — Sharp MX2700

Code: F2-78

Description: Registration exclusive image density sensor trouble (Transfer belt surface reflection ratio abnormality)
The transfer belt surface is scanned by the image density sensor before starting the registration, and adjust the sensor gain so that the output is kept at a certain level. However, the output is not within the specified range though the senor gain is adjusted.
Causes: Image density sensor trouble, harness connection trouble between PCU PWB and the image density sensor, image density sensor dirt, transfer belt cleaning trouble, calibration plate solenoid operation trouble
Remedy: Check the sensor and the harness. Check the calibration plate solenoid operation and the transfer belt surface state. If the trouble is not cleared, replace the image sensor exclusively used for registration, replace the transfer belt, replace the calibration plate, replace the solenoid, or replace the PCU PWB according to the check result.

← Xem tất cả mã lỗi Sharp MX2700

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie