Code: F2-45
Description: Color exclusive image density sensor trouble (Calibration plate surface reflection ratio abnormality)
The calibration plate surface is scanned by the image density sensor before starting the process control, and adjust the sensor gain so that the output is kept at a certain level. However, the output is not within the certain level though the senor gain is adjusted.
The calibration plate surface is scanned by the image density sensor before starting the process control, and adjust the sensor gain so that the output is kept at a certain level. However, the output is not within the certain level though the senor gain is adjusted.
Causes: Image density sensor trouble, harness connection trouble between PCU PWB and the image density sensor, image density sensor dirt, calibration plate dirt, calibration plate solenoid operation trouble
Remedy: Use SIM44-2 to execute the process control gain adjustment. If "ERROR" is displayed, check the sensor and the harness. If the adjustment is completed, check the calibration plate solenoid operation.