Code: E7-20
Description: LSU BD detection trouble
LSU BD signal is not detected.
LSU BD signal is not detected.
Causes: Disconnection or improper connection of harness and connector between LD/BD PWB and LSUcnt PWB
1) Optical axis shift 2) BK laser deterioration, power reduction 3) BD PWB trouble
1) Optical axis shift 2) BK laser deterioration, power reduction 3) BD PWB trouble
Remedy: Case 1 Cause Disconnection or improper connection of harness and connector between LD/BD PWB and LSUcnt PWB Check and remedy Check connection of the harness of each PWB inside the LSU. Case 2 Cause 1) Optical axis shift 2) BK laser deterioration, power reduction 3) BD PWB trouble Check and remedy 1) Use SIM61-1 to check the LSU operation. 2) Replace the LSUcnt/BD PWB. 3) If the trouble cannot be removed by the above 1) to 2), replace the LSU.