Description: Toner cartridge CRUM error (CYAN) CRUM cannot be read or written.
Causes: Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. CRUM trouble Control PWB (PCU) trouble
Remedy: Case 1 Cause Connection trouble or disconnection of the connector and the harness between the PCU and the toner cartridge. Check and remedy Check the connector and the harness between the PCU and the toner cartridge. Case 2 Cause CRUM trouble Check and remedy Replace the toner cartridge. Case 3 Cause Control PWB (PCU) trouble Check and remedy Replace the PCU PWB.