Mã lỗi F2-86 — Sharp MX2700N

Code: F2-86

Description: Half tone process control 2nd patch reference value trouble (MAGENTA)
The low-density section output is greater than the middle-density section output when connecting the low-density section approximation formula and the middle-density section approximation formula (formula of the sensor output ratio for the LSU PWM value) from the second step patch print result when executing the half tone process control in MAGENTA.
Causes: Image density sensor trouble, harness connection trouble between PCU sub PWB and the image density sensor, image density sensor dirt, transfer belt cleaning trouble
Remedy: Use SIM44-2 to execute the process control gain adjustment. If "ERROR" is displayed, check the sensor and the harness. If the adjustment is completed, check the drum surface state and the belt surface state.