Code: L4-30
Description: Controller fan/HDD fan motor trouble
1) The motor lock signal is detected during rotation of the controller fan motor. 2) The motor lock signal is detected during rotation of the HDD fan motor.
1) The motor lock signal is detected during rotation of the controller fan motor. 2) The motor lock signal is detected during rotation of the HDD fan motor.
Causes: Fan motor trouble Harness connection trouble between the mother PWB and the fan motor. Control circuit trouble Mother PWB trouble.
Remedy: Case 1 Cause Fan motor trouble Check and remedy Use SIM6-2 to check the operation of the fan motor. Case 2 Cause Harness connection trouble between the mother PWB and the fan motor. Check and remedy Check the harness and the connector between the mother PWB and the fan motor. Case 3 Cause Control circuit trouble Check and remedy Replace the controller PWB. Case 4 Cause Mother PWB trouble. Check and remedy Replace the mother PWB.